Automatic Chemical Dosing System for Hot Tubs

Eliminate manual testing with our Automatic Dosing System for Hot Tubs HSG282. Maintain perfect water quality effortlessly and enjoy peace of mind!

£2,695.00

Description

An all-in-one solution for automatic control of pH and chlorine levels in swimming pool, hot tub, and spa water. With Cloud connectivity.

A revolutionary system suitable for the Holiday Rental Business.  Test and maintain your hot tub water remotely!  No more physical tests and balancing of pH or chlorine levels twice per day.  Now it can all be done via the Automatic Dosing System brought to you by Heavenly Hot Tubs and Swim Spas.

– Reduced manual dosing time for hot tubs and pools

– Automatic chemical balancing

– Compliance with HSG282 guidelines

– Staff cost savings

– Decreased chemical expenditure

– Access to real-time and historical data for all modules

– High & low alarms to alert staff when issues arise

– Significant savings & return on investment

– Enhanced customer satisfaction

**We can supply a fully lockable GRP enclosure upon request.

‘- Reduced manual dosing time for hot tubs and pools

– Automatic chemical balancing

– Compliance with HSG282 guidelines

– Staff cost savings

– Decreased chemical expenditure

– Access to real-time and historical data for all modules

– High & low alarms to alert staff when issues arise

– Significant savings & return on investment

– Enhanced customer satisfaction

Specifications BL-122

pH range 0.00 to 14.00pH
pH Resolution 0.01pH
pH Accuracy (@25°C +-0.05pH
pH Calibration pH buffer calibration automatic, two-point (4.01, 7.01, 10.01pH); pH process calibration: single point, adjustable
pH controller Proportional feed using adjustable set point and adjustable proportional band; delay to start at power-on and overdosing protection using over feed safety timer
mV range +-2000mV
mV Resolution 1mV
mV Accuracy @ 25°C +-5mV
ORP (mV) calibration single-point, adjustable
ORP Controller Proportional feed using adjustable set point and adjustable proportional band; delay to start at power-on and overdosing protection using over feed safety timer, pH regulator interlocked
Temperature ËšC range -5.0 to 105.0ËšC
ËšC Resolution 0.1ËšC
˚C Accuracy @25°C +-1˚C
Temperature Compensation automatic, -5.0 to 105.0ËšC for pH
Additional Specifications
Alarms High and low with enable/disable option for all parameters. Alarm is triggered after five consecutive readings over/under threshold.
Log Features: • Automatic log
• 60 days logging with 10 seconds period (or 100 logs)
• pH/ORP/temperature measurements
• Events: alarms/errors/power outage
• Recall table/graphic modes
• Export on USB Key
• Log files in CSV format
Ethernet input Ethernet connector (Rj-45) 10/100 Mbps connection
Pump control pump flow control 0.5 to 3.5 L/h (0.13 to 0.92 G/hour) and maximum output pressure 1 atm (14 psi) manual control for each pump
Alarm System Intuitive alert system based on LED colour coded alarm system
Alarm filtering options
Alarm relay control based on user set up filters
Password Protection Set up, calibration and log recall features are password protected
Storage interface USB
GLP pH/ORP
Alarm Relay Output (1) SPDT 5A/230 VAC; activated by selectable pH/ORP/temperature alarm conditions
Digital inputs (3) Galvanic isolated, powered contact type
One input for low level in acid/base tank (contact open)
One input for low level in chlorine tank (contact open)
One input for Hold mode (contact open)
Probe input (1) Probe type: HI-1036-18XX pH/ORP/temperature/matching pin, combined digital probe with DIN waterproof connector; Galvanic isolation; RS48S interface
Power supply 100-240 VAC
Power consumption 15 VA
Environment 0 to 50°C, max 95% RH non-condensing
Dimensions 245 x 188 x 55 mm (73mm with pumps)
Weight 1700g
Casing Wall mounted built-in pump, IP65 rated
In Line Configuration:
BL-122-10 (Analogue outputs) pH/ORP, temperature pool controller is supplied with HI-1036-1802 pH/ORP/temperature digital probe with matching pin, 50 mm probe saddle (1), fitting for probe, chemical injectors (2), 50 mm saddle for injectors (2), peristaltic tubing (2), 5m of injection tubing, aspiration filter (2), 20ml sachets containing pH 7.01 buffer (3), 20ml sachets containing pH 4.01 buffer (3), 20ml sachet of 470mV ORP test solution, power cable and instruction manual, quality certification for meter and probe.
User Panel Flow Cell Configuration:
BL-122-20 (Analogue outputs) pH/ORP/Temperature pool controller is supplied with HI-1036-1802 pH/ORP/temperature digital probe with matching pin, two valves for flow-cell connections with fittings and tubing 10m, saddle for valves 50mm (2), saddle for electrode 50mm (1), fittings for electrode injector (2), saddle for injectors 50mm (2), peristaltic pump tubing (2), aspiration (5m) & injection (5m) tubing, aspiration filter (2), 20ml sachets containing pH 7.01 buffer (3), 20ml sachets containing pH 4.01 buffer (3), 20ml sachet of 470mV ORP test solution, power cable and instruction manual, quality certification for meter and probe.
Cloud Connectivity
BL-122 device are connected to Hanna Cloud using a secured connection. • Ethernet (RJ45) 10/100 Mbps connection
• device Identity Registry
• policy-based authorisation of security keys
The instrument will send status information to Hanna Cloud with a defined period. • readings: pH, ORP, temperature
• events: alarms/warnings/errors
• peripheral status: LEDs
• last dosed acid and chlorine volumes
• GLP info
The instrument will send setup information to Hanna Cloud at startup and whenever the setup is changed on the instrument. • alarm settings
• dosing settings
• general settings
• system: meter information (model, FW version, OS version, serial number), probe information (type, FW version, serial number)
The BL-122 “Remote Hold“ mode: • is an emergency mode that can be remotely triggered via web application
• in this mode the pumps are deactivated
• can be cancelled manually from the controller menu

Reviews

There are no reviews yet.

Be the first to review “Automatic Chemical Dosing System for Hot Tubs”

Your email address will not be published. Required fields are marked *